Summary for Test 2021-07-14-27-6

Test performed: ASTM C191-13

Project Information

Project IdentifiersProject ID: 8801
DEA: AML-CEM
EFIS: AML-CEM
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for Cementitious Materials for use in Concrete Authorized Material List (AML)
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date07/14/2021 Sample Unique Key27
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/14/2021
Sample typeAnnual Source Testing A brief description of the sampleType II/IV Portland Cement
The quantity of what the sample constitutes1 Bucket From where was the sample collectedSource
First name of sampler or witnessed byna Last name of sampler or witnessed byna
Title of sampler Telephone number of sampler
Laboratory sample identificationCM215140 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCALPORTLAND Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeCementitious BrandCalPortland
MillMojave Type of Cementitious MaterialType II/V Cement

Test Details

DIME Sample ID: 2021-07-14-27
DIME Test ID: 2021-07-14-27-6
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C191-13: Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle
Test Release Date: 2021-10-14

Test Results


Input Type: Calculated
Tester's full name: Benjamin Lenz
Date of test: 10/14/2021
Type of Water Used: Type IV grade reagent water
Initial time of setting: 142 min
Final time of setting: no data
General comments (publicly viewable) (Max 1000 characters): Automated Vicat used

Test was verified on 10/14/2021