Summary for Test 2021-09-20-39-1

Test performed: AASHTO T315-20

Project Information

Project IdentifiersProject ID: 214492
DEA: 033F5404
EFIS: 0313000136
DIST-CO-RTE-PM03-SAC-99,160-4.5/5.7,R44.5
Award Date01/24/2020
Closeout Date07/28/2022
Work DescriptionFURNISH PRECAST PRESTRESSED CONCRETE SLAB & PLACE STRUCTURAL CONCRETE.
Location DescriptionSACRAMENTO COUNTY NEAR GALT ON ROUTE 99 FROM NORTH OF MINGO ROAD TO SOUTH OF ARNO ROAD OVERCROSSING AND IN SACRAMENTO ON ROUTE 160 AT AMERICAN RIVER BRIDGE
QA Service Level1 (Verified on 10/23/2019)

Sample Information

Sample Taken Date09/20/2021 Sample Unique Key39
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/01/2021
Sample typeAcceptance A brief description of the sample64-10
The quantity of what the sample constitutes1 can From where was the sample collectedManufacturer
First name of sampler or witnessed byJon Last name of sampler or witnessed byBlumer
Title of samplerTeichert tech Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameTeichert Perkins Batch Plant, from Valero Benecia Transportation Laboratory (TL) Numberc850283
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 64-10
ModifiedNo Lot number1
Sublot number1 Tank number
Time of sample HMA SupplierTeichert Perkins Batch Plant
Certified Asphalt SupplierValero Marketing & Supply - Benicia CA MultigradeNo
Multigrade Type Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2021-09-20-39
DIME Test ID: 2021-09-20-39-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-10-12

Test Results


Phase: Original binder
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 10/06/2021
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.00 %
Stress Amplitude: 0.184 kPa
Phase Angle (δ) (for the 10 cycles): 86.8 degree
Complex Modulus (G*) (for the 10 measurements): 1.532 kPa
Test Temperature (Specimen 1): 64.0 C
Dynamic Shear, G*/sin(δ): 1.53 kPa
General comments (publicly viewable) (Max 1000 characters): ORG

Test was verified on 10/12/2021