Summary for Test 2021-07-22-46-3
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 07/22/2021 | Sample Unique Key | 46 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/22/2021 |
Sample type | Informational | A brief description of the sample | RAP |
The quantity of what the sample constitutes | 3 boxs | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | GARCO | Last name of sampler or witnessed by | GARCO |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Granite Santa Clara Plant | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Reclaimed Asphalt Pavement | RAP Source | Stevens Creek |
---|---|---|---|
Aggregate Size | Aggregate Source | ||
RAP Stockpile | Static | Stockpile Size (tons) | |
Reclaimed Asphalt Pavement Mix Number | Not set |
Test Details
DIME Sample ID: 2021-07-22-46
DIME Test ID: 2021-07-22-46-3
Testing Lab: Granite Construction Company - Coastal
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2021-10-08
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Gordon Pham
Date of test: 07/22/2021
Test procedure used?: no data
Mass of HMA Sample prior to ignition: 0.0 g
Mass Loss: 0.0 g
Correction Factor (Percent by mass of HMA Specimen): 1.89 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: no data
Corrected Asphalt Binder Content: 6.72 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/8/2021 ✔