Summary for Test 2021-10-05-12-1
Test performed: ASTM A416-15
Warning: The test results shown on this page have been superseded and are invalid.
This information is for reference only.
Please click this
link
to view the corrected test.
Project Information
Project Identifiers | Project ID: 993111 DEA: 010L2304 EFIS: 0121000086 |
---|---|
DIST-CO-RTE-PM | 01-DN-101-15.1/15.5 |
Award Date | 06/21/2021 |
Closeout Date | Not set |
Work Description | Last Chance Grade Landslide Repair |
Location Description | Last Chance Grade at Hwy 101 PM 15.1 to 15.5 |
QA Service Level | 1 (Verified on 07/07/2021) |
Sample Information
Sample Taken Date | 10/05/2021 | Sample Unique Key | 12 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/05/2021 |
Sample type | Quality Assurance | A brief description of the sample | .6in Prestressing Strand |
The quantity of what the sample constitutes | 49 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Don | Last name of sampler or witnessed by | Hiranaga |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Sumiden Wire | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM4 - Prestressing Strand | Comments | |
---|---|---|---|
Reel/Coil/Pack Number(s) | Number of Coils | ||
Group Number | 10983 | Strand Diameter | .6 in |
Grade | 270 | Strand Specification | ASTM A 416 |
Heat Number(s) | S0224548, S0225051, S0225050, S0225044, S0225046 | Mfg. Lot Number(s) | NA |
Manufacturer(s) | Sumiden Wire |
Test Details
DIME Sample ID: 2021-10-05-12
DIME Test ID: 2021-10-05-12-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2021-10-07
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 10/06/2021
UTM: 120KIP
Temperature: 72 f
Extensometers: E88768
Num | Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By |
---|---|---|---|---|---|---|---|---|
1 | S0225048 | S335920-1 | 0.217 | 61332 | 58657.4 | 0 | 1.84 | bewing |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 10/7/2021 ✔
Warning: The test results shown on this page have been superseded and are invalid.
This information is for reference only.