Summary for Test 2021-09-20-1-1

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 215486
DEA: 040A0204
EFIS: 0400000129
DIST-CO-RTE-PM04-SON-1-15-15.7
Award DateNot set
Closeout DateNot set
Work DescriptionConstruct roadway and bridge with structural concrete and CIDH piling
Location DescriptionDistrict-County-Route-Post Mile: 04-Son-1-R15.0/R15.7
QA Service Level1 (Verified on 04/08/2022)

Sample Information

Sample Taken Date09/20/2021 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/28/2021
Sample typeQuality Control A brief description of the sample5/8 x 3-1/2 a325 boilts
The quantity of what the sample constitutes95 From where was the sample collectedDistributor
First name of sampler or witnessed byOscar Last name of sampler or witnessed byVizcaino
Title of sampler Telephone number of sampler6787558969
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameSt Louis Screw and Bolt Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)TT0145880
Heat Number(s)20378880 Nut Mfg. Lot Number(s)32805-6215177505
Washer Mfg. Lot Number(s)D9402 Bolt SpecificationA-325
Bolt Length(s)3-1/2" Nut SpecificationA563
Washer SpecificationF436 FinishMechanical B695
Diameter/Size5/8" Bolt Mfg. Lot NumberM4588
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2021-09-20-1
DIME Test ID: 2021-09-20-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2021-10-01

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 09/29/2021
UTM: 450kip
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
1103967431134A325fsaylor

General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 10/1/2021