Summary for Test 2021-08-02-44-2

Test performed: AASHTO T51-13

Project Information

Project IdentifiersProject ID: 44444
DEA: ASCP
EFIS: ASCP
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Asphalt Supplier Certification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date08/02/2021 Sample Unique Key44
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/13/2021
Sample typeVerification A brief description of the samplePG64-28
The quantity of what the sample constitutes2 quart cans, split sample From where was the sample collectedSupplier
First name of sampler or witnessed byReeve Last name of sampler or witnessed byPaxon
Title of samplerCOC Program Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameAlbina - Madras, OR Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 64-28
ModifiedNo Lot number
Sublot number Tank number
Time of sample8/2/2021 8am HMA Supplier
Certified Asphalt SupplierAlbina Asphalt - Madras Plant - Madras OR MultigradeYes
Multigrade TypePG 64-28 / PG 64-16 / PG 64-10 Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2021-08-02-44
DIME Test ID: 2021-08-02-44-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T51-13: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Test Release Date: 2021-09-27

Test Results


Is a normal test obtainable?: Yes
Number of replicates tested: One
Input Type: Measured
Tester's full name: Erika Gonzalez
Date of test: 09/24/2021
Ductility of test #1 (D1): 85 cm
Ductility of sample: 85 cm
General comments (publicly viewable) (Max 1000 characters): per 2018 standard specifications

Test was verified on 9/27/2021