Summary for Test 2021-08-30-49-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 215350
DEA: 081E0604
EFIS: 0813000140
DIST-CO-RTE-PM08-SBD-18-97.0/99.5
Award Date02/23/2021
Closeout Date01/23/2023
Work DescriptionWIDEN ROADWAY WITH HMA, MINOR CONCRETE & MODIFY SIGNAL & LIGHTING.
Location DescriptionSAN BERNARDINO COUNTY IN VICTORVILLE FROM AMARGOSA ROAD TO COBALT ROAD
QA Service Level1 (Verified on 06/23/2021)

Sample Information

Sample Taken Date08/30/2021 Sample Unique Key49
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/31/2021
Sample typeQuality Assurance A brief description of the sampletest 1 at 921 of 10cy out
The quantity of what the sample constitutes1 bag From where was the sample collectedManufacturer
First name of sampler or witnessed bydizhou Last name of sampler or witnessed byou
Title of samplertet Telephone number of sampler
Laboratory sample identificationtest 1 10 cy out Linked DIME Sample ID
The fabricator/manufacturer/facility nameHi Grade - Oro Grande Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-36-0046
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedPlant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1-1/2 inch
The concrete mix design numberct505f25 Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2021-08-30-49
DIME Test ID: 2021-08-30-49-1
Testing Lab: CT D08 - Barstow Field Laboratory 1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2021-09-20

Test Results


What type of gradation is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: dizhou ou
Date of test: 08/31/2021
Cumulative percent passing the 2 in. sieve: 0 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 99 %
Cumulative percent passing the 3/4 in. sieve: 78 %
Cumulative percent passing the 1/2 in. sieve: 0 %
Cumulative percent passing the 3/8 in. sieve: 23 %
Cumulative percent passing the #4 sieve: 6 %
Cumulative percent passing the #8 sieve: 1 %
Cumulative percent passing the #16 sieve: 56 %
Cumulative percent passing the #30 sieve: 38 %
Cumulative percent passing the #50 sieve: 20 %
Cumulative percent passing the #100 sieve: 8 %
Cumulative percent passing the #200 sieve: 3 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/20/2021