Summary for Test 2021-08-20-45-3
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 214114 DEA: 040A5394 EFIS: 0418000244 |
---|---|
DIST-CO-RTE-PM | 04-SOL-80,12-11.4/12.8, 2.1/2.8 |
Award Date | Not set |
Closeout Date | 02/24/2023 |
Work Description | Widen EB SR-12 Connector, Construct 3 ramps & 2 box girder bridges, remove existing bridge, etc. |
Location Description | I-80/I-680/Route 12 Interchange |
QA Service Level | 1 (Verified on 04/23/2019) |
Sample Information
Sample Taken Date | 08/20/2021 | Sample Unique Key | 45 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 08/20/2021 |
Sample type | Verification | A brief description of the sample | 16 Boxes of HMA |
The quantity of what the sample constitutes | 16 boxes of 1/2" Type A HMA with RAP | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | (Plant QC Rep) | Last name of sampler or witnessed by | (Plant QC Rep) |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Syar Vallejo | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | |
Sublot number | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2021-08-20-45
DIME Test ID: 2021-08-20-45-3
Testing Lab: CT D04 - Hayward DME / District Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2021-09-15
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Randy Cortez
Date of test: 09/07/2021
Test procedure used?: Method A
Mass of the specimen basket assembly: no data
Mass of the specimen and specimen basket assembly prior to ignition: no data
Mass of HMA Sample prior to ignition: 1546.1 g
Mass Loss: no data
Mass of aggregate remaining after ignition: 1421.0 g
Correction Factor (Percent by mass of HMA Specimen): 1.94 %
Moisture Content: 0.00 %
Temperature Compensation Factor: no data
Test Temperature: 900 F
Corrected Asphalt Binder Content: 6.15 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/15/2021 ✔