Summary for Test 2021-09-02-30-2

Test performed: CTM 523-May 2020

Project Information

Project IdentifiersProject ID: 215188
DEA: 080F5434
EFIS: 0817000239
Permit Numbers: 0823NMC0369
DIST-CO-RTE-PM08-RIV-I-15,SR-91-6.1-7.6
Award Date03/11/2020
Closeout DateNot set
Work DescriptionI-15 ELC: 15/91 Express Lanes Connector Project (ELC)
Location DescriptionJunction of I-15 and SR-91 in Corona, CA
QA Service Level1 (Verified on 09/16/2020)

Sample Information

Sample Taken Date09/02/2021 Sample Unique Key30
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/03/2021
Sample typeAcceptance A brief description of the sampleConcrete beams
The quantity of what the sample constitutes4 Beams From where was the sample collectedJob Site
First name of sampler or witnessed byJames / Kevin Last name of sampler or witnessed byBurton / Oluoha
Title of sampler Telephone number of sampler
Laboratory sample identification1JA1, 1JA2, 1JB1, 1JB2 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCemex, Fontana Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design number1605762
The truck number from where the sample was collected The batch plant ticket number from where the sample was collectedTTI
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedOn Job Site at Concrete Truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2021-09-02-30
DIME Test ID: 2021-09-02-30-2
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: CTM 523-May 2020: Method of Test for Flexural Strength of Concrete
Test Release Date: 2021-09-13

Test Results


Number of specimens:
Unit system used?: US Units
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Is a beam dimensional correction factor used?: No
Input Type: Calculated
Tester's full name: k. Talati, R. Osorio
Date of test: 09/12/2021
Identification number: 1JA2
Width of specimen: 5.94 inch
Depth of specimen: 6.00 inch
Span length of specimen: 18 inch
Maximum load applied: 7350 lb
Curing history and apparent moisture condition of the specimen: moist, curing room
If specimen was capped, ground or if leather shims were used: No
Defects in specimen: None
Age of specimen: 10 days
Age of specimen in hours: no data
Modulus of rupture: 650 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/13/2021