Summary for Test 2021-08-30-25-2

Test performed: AASHTO T315-20

Project Information

Project IdentifiersProject ID: 215393
DEA: 021J5104
EFIS: 0220000086
DIST-CO-RTE-PM02-LAS,MOD-139-57.0/66.635,0.0/0.1
Award Date02/10/2021
Closeout Date11/24/2021
Work DescriptionPERFORM COLD IN-PLACE RECYCLING AND PLACE HOT MIX ASPHALT (TYPE A).
Location DescriptionLASSEN AND MODOC COUNTIES NEAR ADIN FROM 4.5 MILES SOUTH OF COUNTY ROAD A2 TO 0.1 MILE SOUTH OF ROUTE 299
QA Service Level1 (Verified on 01/07/2021)

Sample Information

Sample Taken Date08/30/2021 Sample Unique Key25
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/03/2021
Sample typeAcceptance A brief description of the sampleBINDER
The quantity of what the sample constitutes1 OF 2 CANS, #1 TEST From where was the sample collectedSource
First name of sampler or witnessed byE Last name of sampler or witnessed byCHAVEZ
Title of samplerMATLS Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameKLAMATH FALLS, OR Transportation Laboratory (TL) NumberC848953
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 58-34 M
ModifiedYes Lot number
Sublot number Tank number
Time of sample HMA SupplierCONTRACTOR HAT CREEK
Certified Asphalt SupplierAlbina Asphalt - Klamath Falls Plant - Klamath Falls OR MultigradeNo
Multigrade Type Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2021-08-30-25
DIME Test ID: 2021-08-30-25-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-09-15

Test Results


Phase: Original binder
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 09/08/2021
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.00 %
Stress Amplitude: 0.187 kPa
Phase Angle (δ) (for the 10 cycles): 69.3 degree
Complex Modulus (G*) (for the 10 measurements): 1.555 kPa
Test Temperature (Specimen 1): 58.0 C
Dynamic Shear, G*/sin(δ): 1.66 kPa
General comments (publicly viewable) (Max 1000 characters): Per 2018 Standard Specifications ORIG

Test was verified on 9/15/2021