Summary for Test 2021-08-13-33-1
Test performed: AASHTO T209-12Project Information
Project Identifiers | Project ID: 215605 DEA: 040W3904 EFIS: 0420000212 |
---|---|
DIST-CO-RTE-PM | 04-CC-160-L1.1/0.6 |
Award Date | 05/10/2021 |
Closeout Date | 06/29/2023 |
Work Description | COLD PLANE AC PAVEMENT AND PLACE HMA (A). |
Location Description | CONTRA COSTA COUNTY IN ANTIOCH FROM 0.2 MILE SOUTH OF MAIN STREET TO 0.1 MILE NORTH OF WILBUR AVENUE |
QA Service Level | 1 (Verified on 04/12/2021) |
Sample Information
Sample Taken Date | 08/13/2021 | Sample Unique Key | 33 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 08/13/2021 |
Sample type | Verification | A brief description of the sample | 1 Bag of RAP Sampled pt e plant |
The quantity of what the sample constitutes | 1 Bag | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Clint | Last name of sampler or witnessed by | Rogers |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | ABM ANTIIOCH | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Reclaimed Asphalt Pavement | RAP Source | ABM |
---|---|---|---|
Aggregate Size | Aggregate Source | ||
RAP Stockpile | Stockpile Size (tons) | ||
Reclaimed Asphalt Pavement Mix Number | Not set |
Test Details
DIME Sample ID: 2021-08-13-33
DIME Test ID: 2021-08-13-33-1
Testing Lab: CT D04 - Hayward DME / District Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2021-09-09
Test Results
Number of tests: 2
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Randy Cortez
Date of test: 08/18/2021
Method Performed: no data
Mass of container filled with water: 7357.0 grams
Mass of oven-dry sample in air for Sample 1: 1571.5 grams
Mass of container filled with the sample and water for Sample 1: 8324.7 grams
Mass of container filled with water: 7357.1 grams
Mass of oven-dry sample in air for Sample 2: 1571.5 grams
Mass of container filled with the sample and water for Sample 2: 8324.3 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.603
Specific Gravity for Sample 2: 2.601
Average Specific Gravity: 2.602
Theoretical maximum density at 25°C (77°F): no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/9/2021 ✔