Summary for Test 2021-08-27-23-1
Test performed: ASTM C39-18Project Information
Project Identifiers | Project ID: 215350 DEA: 081E0604 EFIS: 0813000140 |
---|---|
DIST-CO-RTE-PM | 08-SBD-18-97.0/99.5 |
Award Date | 02/23/2021 |
Closeout Date | 01/23/2023 |
Work Description | WIDEN ROADWAY WITH HMA, MINOR CONCRETE & MODIFY SIGNAL & LIGHTING. |
Location Description | SAN BERNARDINO COUNTY IN VICTORVILLE FROM AMARGOSA ROAD TO COBALT ROAD |
QA Service Level | 1 (Verified on 06/23/2021) |
Sample Information
Sample Taken Date | 08/27/2021 | Sample Unique Key | 23 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/03/2021 |
Sample type | Quality Assurance | A brief description of the sample | concrete cylinders |
The quantity of what the sample constitutes | 2 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Larry | Last name of sampler or witnessed by | Francisco |
Title of sampler | TE | Telephone number of sampler | |
Laboratory sample identification | 1031-827 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Not Provided | Transportation Laboratory (TL) Number | 1031-827 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | CT675F25 |
---|---|---|---|
The truck number from where the sample was collected | Not Provided on TL | The batch plant ticket number from where the sample was collected | Not Provided |
Concrete batch plant | Not Provided | The fabricator/manufacturer designation for the sample | |
A detailed description of where the material sample was collected | site | Where the material sample would have been placed if not sampled | Sta 56000 DS7 South Side Palmdale Road |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2021-08-27-23
DIME Test ID: 2021-08-27-23-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2021-09-04
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 09/04/2021
Average diameter of cylinder 1: 4.03 in
Average diameter of cylinder 2: 4.03 in
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Maximum load on cylinder 1: 48810 lb
Maximum load on cylinder 2: 48250 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 8 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.76 in^2
Cross sectional area of cylinder 2: 12.76 in^2
Compressive strength of cylinder 1: 3825.2 psi
Compressive strength of cylinder 2: 3781.3 psi
Compressive strength (to nearest 10 psi): 3800 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/4/2021 ✔