Summary for Test 2021-08-19-34-1
Test performed: AASHTO T240-17Project Information
Project Identifiers | Project ID: 215500 DEA: 101J1904 EFIS: 1018000132 |
---|---|
DIST-CO-RTE-PM | 10-MER-140-37.4/44.8 |
Award Date | 04/12/2021 |
Closeout Date | 03/23/2022 |
Work Description | COLD IN-PLACE RECYCLING AND RESURFACE PAVEMENT WITH HMA. |
Location Description | MERCED COUNTY IN AND NEAR MERCED FROM SANTA FE AVENUE TO HAYDEN ROAD |
QA Service Level | 1 (Verified on 03/23/2021) |
Sample Information
Sample Taken Date | 08/19/2021 | Sample Unique Key | 34 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/25/2021 |
Sample type | Department Acceptance | A brief description of the sample | TEST 8/19, NO test 8/16-17,18,22 |
The quantity of what the sample constitutes | 1 of 2 cans | From where was the sample collected | Source |
First name of sampler or witnessed by | M | Last name of sampler or witnessed by | Cozad |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Marathon | Transportation Laboratory (TL) Number | 034992 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-28 |
---|---|---|---|
Modified | Yes | Lot number | 1 |
Sublot number | 10 | Tank number | |
Time of sample | HMA Supplier | ||
Certified Asphalt Supplier | Marathon Petroleum Co. LP - Elk Grove CA | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-08-19-34
DIME Test ID: 2021-08-19-34-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2021-09-03
Test Results
Is mass change based on one or two containers?: Two
Input Type: Measured
Tester's full name: Harish Thakur
Date of test: 09/01/2021
Any material loss from containers during heating process/testing?: No
Mass of empty container #1: 156.015 grams
Mass of empty container #2: 174.668 grams
Mass of container #1 before test (m1i): 190.964 grams
Mass of container #2 before test (m2i): 211.729 grams
Mass of container #1 after test (m1f): 190.722 grams
Mass of container #2 after test (m2f): 211.555 grams
Average mass change: -0.581 percent
General comments (publicly viewable) (Max 1000 characters): as per 2018 standard specs
Test was verified on 9/3/2021 ✔