Summary for Test 2021-08-12-37-2
Test performed: AASHTO T315-20Project Information
Project Identifiers | Project ID: 215588 DEA: 101J1004 EFIS: 1018000142 |
---|---|
DIST-CO-RTE-PM | 10-AMA-104-0.0/10.1 |
Award Date | 04/26/2021 |
Closeout Date | 12/07/2021 |
Work Description | COLD PLANE ASPHALT CONCRETE PAVEMENT AND RESURFACE PAVEMENT WITH HMA. |
Location Description | AMADOR COUNTY IN AND NEAR IONE AT VARIOUS LOCATIONS FROM SACRAMENTO COUNTY LINE TO ROUTE 49 |
QA Service Level | 1 (Verified on 03/26/2021) |
Sample Information
Sample Taken Date | 08/12/2021 | Sample Unique Key | 37 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/27/2021 |
Sample type | Department Acceptance | A brief description of the sample | TEST 8/12, NO test 8/16-17 |
The quantity of what the sample constitutes | 1 CAN | From where was the sample collected | Source |
First name of sampler or witnessed by | J | Last name of sampler or witnessed by | Kort |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | MARATHON ELK GROVE | Transportation Laboratory (TL) Number | 034962 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-16 |
---|---|---|---|
Modified | Lot number | ||
Sublot number | Tank number | ||
Time of sample | HMA Supplier | ||
Certified Asphalt Supplier | Marathon Petroleum Co. LP - Elk Grove CA | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-08-12-37
DIME Test ID: 2021-08-12-37-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-10-13
Test Results
Phase: Original binder
Input Type: Measured
Tester's full name: Erika Gonzalez
Date of test: 08/30/2021
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.00 %
Stress Amplitude: 0.099 kPa
Phase Angle (δ) (for the 10 cycles): 88.4 degree
Complex Modulus (G*) (for the 10 measurements): 0.826 kPa
Test Temperature (Specimen 1): 64.0 C
Dynamic Shear, G*/sin(δ): 0.83 kPa
General comments (publicly viewable) (Max 1000 characters): per 2018 standard specifications OG
Test was verified on 10/13/2021 ✔