Summary for Test 2021-08-11-21-3
Test performed: AASHTO T315-20Project Information
Project Identifiers | Project ID: 214919 DEA: 060U4504 EFIS: 0615000298 |
---|---|
DIST-CO-RTE-PM | 06-FRE-168-18.6/T25.5 |
Award Date | 06/16/2020 |
Closeout Date | 07/29/2022 |
Work Description | COLD PLANE AC PAVEMENT AND HOT MIX ASPHALT RESURFACING. |
Location Description | FRESNO COUNTY NEAR PRATHER FROM 0.1 MILE EAST OF SAMPLE ROAD TO OAK CREEK ROAD |
QA Service Level | 1 (Verified on 04/21/2020) |
Sample Information
Sample Taken Date | 08/11/2021 | Sample Unique Key | 21 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/20/2021 |
Sample type | Department Acceptance | A brief description of the sample | PG 64-16 |
The quantity of what the sample constitutes | 1 can | From where was the sample collected | Source |
First name of sampler or witnessed by | Jonathan | Last name of sampler or witnessed by | _ |
Title of sampler | CMI | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | San Joaquin Refinery | Transportation Laboratory (TL) Number | 040577 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-16 |
---|---|---|---|
Modified | Lot number | 1 | |
Sublot number | 10 | Tank number | |
Time of sample | HMA Supplier | ||
Certified Asphalt Supplier | San Joaquin Refinery - Bakersfield CA | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-08-11-21
DIME Test ID: 2021-08-11-21-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-08-30
Test Results
Phase: RTFO residue
Input Type: Measured
Tester's full name: Erika Gonzalez
Date of test: 08/24/2021
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 10.00 %
Stress Amplitude: 0.248 kPa
Phase Angle (δ) (for the 10 cycles): 88.4 degree
Complex Modulus (G*) (for the 10 measurements): 2.480 kPa
Test Temperature (Specimen 1): 64.0 C
Dynamic Shear, G*/sin(δ): 2.48 kPa
General comments (publicly viewable) (Max 1000 characters): per 2018 standard specifications RTFO
Test was verified on 8/30/2021 ✔