Summary for Test 2021-08-09-10-2

Test performed: AASHTO T84-14

Project Information

Project IdentifiersProject ID: 214523
DEA: 07302504
EFIS: 0713000479
DIST-CO-RTE-PM07-VEN-23-R3.3/R11.5
Award Date02/06/2020
Closeout DateNot set
Work DescriptionPLACE HMA AND JPCP AND INDIVIDUAL SLAB REPLACEMENT.
Location DescriptionVENTURA COUNTY FROM ROUTE 101/23 SEPARATION TO NEW LOS ANGELES AVENUE UNDERCROSSING
QA Service Level1 (Verified on 03/17/2020)

Sample Information

Sample Taken Date08/09/2021 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/10/2021
Sample typeVerification A brief description of the samplePSUE 3/4" HMA-A-SP R15 0.5% LAS
The quantity of what the sample constitutes10 Bags of Aggregate, 1 Bag of Rap From where was the sample collectedManufacturer
First name of sampler or witnessed byMD Last name of sampler or witnessed byShajahan
Title of sampler Telephone number of sampler
Laboratory sample identification0457A-21 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Materials-Sun Valley Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0035::FISH CANYON QUARRY
The fabricator's/manufacturer's product name for the sample3/4 HMA-A-SP R15 The fabricator/manufacturer designation for the sample
The plant number220831 SVA MPC A detailed description of where the material sample was collectedBelt Cut at Vulcan Sun Valley Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2021-08-09-10
DIME Test ID: 2021-08-09-10-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2021-08-18

Test Results


Input Type: Measured
Tester's full name: Danilo Ferrer
Date of test: 08/12/2021
Mass of saturated surface dry sample (before pycnometer) (S): 500 grams
Mass of the pycnometer with water and aggregate (C): 970.4 grams
Mass of the pycnometer with water (B): 653.4 grams
Mass of the oven dried sample (before pycnometer) (A): 493.2 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500 grams
Mass of the oven dry aggregate (for absorption) (A): 493.2 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity: 2.695
Bulk specific gravity (SSD Basis): 2.732
Apparent specific gravity: 2.799
Absorption: 1.4 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/18/2021