Summary for Test 2021-08-04-14-2
Test performed: ASTM D36-14ε1Project Information
Project Identifiers | Project ID: 215465 DEA: 061A8804 EFIS: 0620000178 |
---|---|
DIST-CO-RTE-PM | 06-FRE-145-0.0/6.0 |
Award Date | 03/18/2021 |
Closeout Date | 03/02/2022 |
Work Description | COLD PLANE AC PAVEMENT AND RESURFACE ROADWAY WITH HMA AND RHMA. |
Location Description | FRESNO COUNTY NEAR FIVE POINTS FROM ROUTE 145/5 SEPARATION TO COLUSA AVENUE. |
QA Service Level | 1 (Verified on 02/08/2021) |
Sample Information
Sample Taken Date | 08/04/2021 | Sample Unique Key | 14 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/09/2021 |
Sample type | Acceptance | A brief description of the sample | Rubberized PG64-16 |
The quantity of what the sample constitutes | 1 can | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Rick | Last name of sampler or witnessed by | _ |
Title of sampler | Granite Tech | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Granite Coalinga | Transportation Laboratory (TL) Number | c039914 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Rubber Binder | Asphalt modifier supplier | |
---|---|---|---|
Performance Grade | PG 64-16 | Lot number | |
Sublot number | Asphalt Rubber Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-08-04-14
DIME Test ID: 2021-08-04-14-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Test Release Date: 2021-08-16
Test Results
ASTM Thermometer used?: C
Input Type: Measured
Tester's full name: Minoo Ahmadi
Date of test: 08/13/2021
Softening Point Sample 1: 66 C
Softening Point Sample 2: 66 C
Bath Liquid: USP glycerin
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters): 2018 per spec.
Test was verified on 8/16/2021 ✔