Summary for Test 2021-08-09-11-2

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 214841
DEA: 034H1004
EFIS: 0318000176
DIST-CO-RTE-PM03-SIE-49-9.2/24.7
Award Date05/29/2020
Closeout Date07/29/2022
Work DescriptionINSTALL RETAINING STRUCTURE AND RSP CONCRETE EMBANKMENT.
Location DescriptionSIERRA COUNTY ON ROUTE 49 AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 03/24/2020)

Sample Information

Sample Taken Date08/09/2021 Sample Unique Key11
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/10/2021
Sample typeQuality Assurance A brief description of the sampleBar Lock Coupler
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byAndrew Last name of sampler or witnessed byDavis
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameErico Lenton Nucor Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerErico Lenton Intermediate Assembler or Fabricator
Rebar Size#8 Coupler ModelBar Lock B series
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)H11503779xx J0003 Rebar Heat Number(s)3500019018
Rebar Size 2 Coupler Unique IDNot set

Test Details

DIME Sample ID: 2021-08-09-11
DIME Test ID: 2021-08-09-11-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2021-08-11

Test Results


Number of Samples Tested: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 08/10/2021
UTM: 400kip
Temperature: 72.00 f
Halo ID:
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
12No. 8/25mm100.797868399599OK Neckingfsaylor

General comments (publicly viewable) (Max 1000 characters): OK Necking
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 8/11/2021