Summary for Test 2021-07-27-22-1

Test performed: AASHTO T240-17

Project Information

Project IdentifiersProject ID: 214190
DEA: 024G41U4
EFIS: 0218000047
DIST-CO-RTE-PM02-SIS,SIS-5-Var
Award Date08/26/2019
Closeout Date11/24/2021
Work DescriptionREPLACE REINFORCED CONCRETE BRIDGES & CONSTRUCT RETAINING WALL.
Location DescriptionSHASTA AND SISKIYOU COUNTIES ABOUT 7 MILES NORTH OF POLLARD FLAT FROM 0.8 MILE SOUTH TO 0.7 MILE NORTH OF SIMS ROAD UNDERCROSSING AND FROM 0.6 MILE SOUTH OF CASTLE CRAGS DRIVE UNDERCROSSING TO 0.2 MILE SOUTH OF SOUTH DUNSMUIR UNDERCROSSING
QA Service Level1 (Verified on 07/09/2019)

Sample Information

Sample Taken Date07/27/2021 Sample Unique Key22
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/03/2021
Sample typeAcceptance A brief description of the samplePG 58-34M
The quantity of what the sample constitutes1 OF 2 Cans From where was the sample collectedSource
First name of sampler or witnessed byRandy Last name of sampler or witnessed byBibbins
Title of samplerCGI Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameValero Benicia Transportation Laboratory (TL) Number990947
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 58-34 M
ModifiedYes Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierValero Marketing & Supply - Benicia CA MultigradeNo
Multigrade Type Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2021-07-27-22
DIME Test ID: 2021-07-27-22-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2021-08-12

Test Results


Is mass change based on one or two containers?: Two
Input Type: Measured
Tester's full name: Harish Thakur
Date of test: 08/10/2021
Any material loss from containers during heating process/testing?: No
Mass of empty container #1: 159.976 grams
Mass of empty container #2: 166.405 grams
Mass of container #1 before test (m1i): 195.822 grams
Mass of container #2 before test (m2i): 201.811 grams
Mass of container #1 after test (m1f): 195.624 grams
Mass of container #2 after test (m2f): 201.614 grams
Average mass change: -0.554 percent
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/12/2021