Summary for Test 2021-06-17-50-6
Test performed: AASHTO T269-14Project Information
Project Identifiers | Project ID: 215627 DEA: 032G2004 EFIS: 0321000024 |
---|---|
DIST-CO-RTE-PM | 03-YOL-128-0.0/9.8 |
Award Date | 05/11/2021 |
Closeout Date | 01/20/2022 |
Work Description | PLACE RHMA AND REPLACE ASPHALT CONCRETE. |
Location Description | YOLO COUNTY IN AND NEAR WINTERS FROM PUTAH CREEK BRIDGE TO ROUTE 128/505 SEPARATION |
QA Service Level | 1 (Verified on 03/29/2021) |
Sample Information
Sample Taken Date | 06/17/2021 | Sample Unique Key | 50 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/21/2021 |
Sample type | Verification | A brief description of the sample | 3/4" RHMA-G |
The quantity of what the sample constitutes | 32 boxes of mix | From where was the sample collected | Supplier |
First name of sampler or witnessed by | Sam | Last name of sampler or witnessed by | Mosallem |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Teichert Woodland Plant | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | |
Sublot number | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2021-06-17-50
DIME Test ID: 2021-06-17-50-6
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Test Release Date: 2021-08-10
Test Results
Number of tests: 3
Is the sample lab compacted or field compacted?:
Input Type: Calculated
Tester's full name: Terrance White
Date of test: 07/29/2021
Percent Air Voids: 2.8 %
Percent Air Voids 2: 2.8
Percent Air Voids 3: 2.7
Average Percent Air Voids: 2.8
General comments (publicly viewable) (Max 1000 characters): JMF 21-031
Test was verified on 8/10/2021 ✔