Summary for Test 2021-07-26-24-1
Test performed: AASHTO T240-17Project Information
Project Identifiers | Project ID: 215465 DEA: 061A8804 EFIS: 0620000178 |
---|---|
DIST-CO-RTE-PM | 06-FRE-145-0.0/6.0 |
Award Date | 03/18/2021 |
Closeout Date | 03/02/2022 |
Work Description | COLD PLANE AC PAVEMENT AND RESURFACE ROADWAY WITH HMA AND RHMA. |
Location Description | FRESNO COUNTY NEAR FIVE POINTS FROM ROUTE 145/5 SEPARATION TO COLUSA AVENUE. |
QA Service Level | 1 (Verified on 02/08/2021) |
Sample Information
Sample Taken Date | 07/26/2021 | Sample Unique Key | 24 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/04/2021 |
Sample type | Department Acceptance | A brief description of the sample | binder |
The quantity of what the sample constitutes | 1 can | From where was the sample collected | Source |
First name of sampler or witnessed by | Garco | Last name of sampler or witnessed by | Garco |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | San Joaquin Refinery | Transportation Laboratory (TL) Number | 056168 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 70-10 |
---|---|---|---|
Modified | No | Lot number | 2190210719 |
Sublot number | Tank number | 9001 | |
Time of sample | 2:29pm | HMA Supplier | Granite |
Certified Asphalt Supplier | San Joaquin Refinery - Bakersfield CA | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-07-26-24
DIME Test ID: 2021-07-26-24-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2021-08-10
Test Results
Is mass change based on one or two containers?: Two
Input Type: Measured
Tester's full name: Harish Thakur
Date of test: 08/04/2021
Any material loss from containers during heating process/testing?: No
Mass of empty container #1: 172.989 grams
Mass of empty container #2: 167.321 grams
Mass of container #1 before test (m1i): 208.947 grams
Mass of container #2 before test (m2i): 202.541 grams
Mass of container #1 after test (m1f): 208.962 grams
Mass of container #2 after test (m2f): 202.553 grams
Average mass change: 0.038 percent
General comments (publicly viewable) (Max 1000 characters): Per 2018 Standard Specifications
Test was verified on 8/10/2021 ✔