Summary for Test 2021-07-08-40-4

Test performed: AASHTO T315-20

Project Information

Project IdentifiersProject ID: 214426
DEA: 030A5704
EFIS: 0300020593
DIST-CO-RTE-PM03-YUB-20-13.3/R18.2
Award Date01/02/2020
Closeout DateNot set
Work DescriptionBrowns Valley Rehab: CONSTRUCT BRIDGE, REALIGN CURVE, WIDEN SHOULDERS AND CULVERT WORK.
Location DescriptionYUBA COUNTY FROM MARYSVILLE ROAD TO THE YUBA RIVER BRIDGE
QA Service Level1 (Verified on 10/23/2019)

Sample Information

Sample Taken Date07/08/2021 Sample Unique Key40
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/26/2021
Sample typeAcceptance A brief description of the samplePG 64-16 Marathon
The quantity of what the sample constitutes1 Can From where was the sample collectedSource
First name of sampler or witnessed byTeichert Personnel (SAMPLER) Last name of sampler or witnessed by-
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameTeichert - Hallwood Plant Transportation Laboratory (TL) Number930972
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
Modified Lot number6
Sublot number1 Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierMarathon Petroleum Co. LP - Elk Grove CA MultigradeNo
Multigrade Type Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2021-07-08-40
DIME Test ID: 2021-07-08-40-4
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-08-11

Test Results


Phase: PAV residue
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 08/03/2021
Test Plate Diameter: 8 mm
Test Gap: 2 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 1.00 %
Stress Amplitude: 42.554 kPa
Phase Angle (δ) (for the 10 cycles): 49.4 degree
Complex Modulus (G*) (for the 10 measurements): 4255.476 kPa
Test Temperature (Specimen 1): 28.0 C
(G*) x sin(δ)=: 3231 kPa
General comments (publicly viewable) (Max 1000 characters): Per 2018 Standard Specifications PAV

Test was verified on 8/11/2021