Summary for Test 2021-06-18-29-1
Test performed: CONCLP 4-16Project Information
Project Identifiers | Project ID: 215523 DEA: 120S2004 EFIS: 1219000105 |
---|---|
DIST-CO-RTE-PM | 12-ORA-22,57-R2.7/R11.9,18.8 |
Award Date | 04/12/2021 |
Closeout Date | 09/08/2022 |
Work Description | PLACE POLYESTER CONCRETE, REPLACE JOINT SEALS AND TREAT BRIDGE DECK. |
Location Description | ORANGE COUNTY AT VARIOUS LOCATIONS ON ROUTE 22 FROM GARDEN GROVE BOULEVARD UNDERCROSSING TO GLASSELL STREET UNDERCROSSING AND ON ROUTE 57 AT BASTANCHURY ROAD UNDERCROSSING |
QA Service Level | 1 (Verified on 05/20/2021) |
Sample Information
Sample Taken Date | 06/18/2021 | Sample Unique Key | 29 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/21/2021 |
Sample type | Quality Control | A brief description of the sample | 2 pints 204, chp, z cure, 8020 |
The quantity of what the sample constitutes | 25000 gallons | From where was the sample collected | Source |
First name of sampler or witnessed by | Daniel | Last name of sampler or witnessed by | Tikusis |
Title of sampler | Telephone number of sampler | 17073309227 | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Kwik Bond Polymers, Benicia | Transportation Laboratory (TL) Number | C943077 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Methacrylate | Mfg. Lot Number(s) | 2170790889 |
---|---|---|---|
Batch number | 2170790889 | Mix number | 3524 |
Test Details
DIME Sample ID: 2021-06-18-29
DIME Test ID: 2021-06-18-29-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 4-16: HMWM
Test Release Date: 2021-07-30
Test Results
Input Type: Calculated
Tester's full name: Spencer Adams
Date of test: 07/15/2021
Viscosity (ASTM D 2196) Brookfield RVT with UL adapter, 50 RPM @ 77 deg F, 25 max cps @ 77 deg F: 20.86
Specific gravity (ASTM D 1475) 0.90 min @ 77 deg F: 7.58
Volatile content (ASTM D 2369) 30% max: 22.29
Flash point (ASTM D 3828) more than 180 deg F: 190
PCC - SSD bond strength (CA Test 551) 500 psi minimum @ 24 hours: 816.343
Tack free time, 400 minutes max: 280
General comments (publicly viewable) (Max 1000 characters): Bond Strength and Tack Free Accepted Based On Supplier Results.
Test was verified on 7/30/2021 ✔