Summary for Test 2021-07-19-12-5
Test performed: AASHTO T176-08Project Information
Project Identifiers | Project ID: 214466 DEA: 081F1414 EFIS: 0815000231 |
---|---|
DIST-CO-RTE-PM | 08-RIV-15-15-54.2/54.3 |
Award Date | 01/02/2020 |
Closeout Date | 05/26/2022 |
Work Description | Slab & lane replacement with JPCP & precast conc pavement, place HMA. |
Location Description | Riverside and San Diego County |
QA Service Level | 1 (Verified on 03/20/2020) |
Sample Information
Sample Taken Date | 07/19/2021 | Sample Unique Key | 12 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/22/2021 |
Sample type | Verification | A brief description of the sample | PSUE 1/2" HMA-A-SP R12, 0.5% LAS |
The quantity of what the sample constitutes | 6 Bags of Combined Aggregate | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Oluoha |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 0421G-21 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | California Commercial Asphalt - Lake Elsinore | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-33-0098, 91-33-0011 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | 1/2 RHMA-G-SP | The fabricator/manufacturer designation for the sample | |
The plant number | 51218180 | A detailed description of where the material sample was collected | Belt Cut at California Commercial Asphalt Lake Elsinore Plant |
Where the material sample would have been placed if not sampled | Asphalt Paving | Primary Aggregate Nominal Size | 1/2 inch |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2021-07-19-12
DIME Test ID: 2021-07-19-12-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2021-07-29
Test Results
How many times will the test be run?: 3 Times
Input Type: Measured
Tester's full name: Larry Diaz
Date of test: 07/27/2021
Clay Level (Test 1): 5.9
Sand Level (Test 1): 4
Clay Level (Test 2): 5.9
Sand Level (Test 2): 4.1
Clay Level (Test 3): 5.6
Sand Level (Test 3): 3.8
Sand Equivalent (Test 1): 68
Sand Equivalent (Test 2): 70
Sand Equivalent (Test 3): 68
Sand Equivalent: 69
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/29/2021 ✔