Summary for Test 2021-07-23-7-5
Test performed: AASHTO T316-17Project Information
Project Identifiers | Project ID: 215609 DEA: 074W9404 EFIS: 0720000196 |
---|---|
DIST-CO-RTE-PM | 07-LA-101-0.0/1.0 |
Award Date | 05/06/2021 |
Closeout Date | 07/14/2022 |
Work Description | COLD PLANE AND OVERLAY WITH RUBBERIZED HOT MIX ASPHALT, SLURRY SEAL. |
Location Description | LOS ANGELES COUNTY IN LOS ANGELES FROM ROUTE 10/101 SEPARATION TO SPRING STREET OVERCROSSING |
QA Service Level | 1 (Verified on 08/17/2021) |
Sample Information
Sample Taken Date | 07/23/2021 | Sample Unique Key | 7 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/27/2021 |
Sample type | Verification | A brief description of the sample | Asphalt Binder Sample |
The quantity of what the sample constitutes | 1 Quart | From where was the sample collected | Supplier |
First name of sampler or witnessed by | Blue Diamond | Last name of sampler or witnessed by | QC |
Title of sampler | QC | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Blue Diamond Material-Irwindale | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-16 |
---|---|---|---|
Modified | Lot number | ||
Sublot number | Tank number | ||
Time of sample | HMA Supplier | ||
Certified Asphalt Supplier | Lunday Thagard Company-World Oil - South Gate CA | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-07-23-7
DIME Test ID: 2021-07-23-7-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T316-17: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2021-08-16
Test Results
Is viscosity reading in cP/Pa-s?: Pa-s
Input Type: Calculated
Tester's full name: Sm Ali
Date of test: 07/28/2021
Time of test: 7:51 HH:MM
Test Temperature: 135 C
Speed: 100 rpm
Spindle size: 21 in
Torque: 80 %
Viscosity reading #1 (A) : 0.401 Pa-s
Viscosity reading #2 (B) : 0.402 Pa-s
Viscosity reading #3 (C): 0.405 Pa-s
Average viscosity: 0.403 Pa-s
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/16/2021 ✔