Summary for Test 2021-07-21-26-2
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 07/21/2021 | Sample Unique Key | 26 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/26/2021 |
Sample type | Quality Assurance | A brief description of the sample | A325 Bolt |
The quantity of what the sample constitutes | 5 | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Mike | Last name of sampler or witnessed by | Hasler |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Ameron International | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | 10633480 | Nut Mfg. Lot Number(s) | |
Washer Mfg. Lot Number(s) | Bolt Specification | F3125 A325 | |
Bolt Length(s) | 4 | Nut Specification | None |
Washer Specification | None | Finish | F2329 |
Diameter/Size | 1 | Bolt Mfg. Lot Number | L294Q1 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2021-07-21-26
DIME Test ID: 2021-07-21-26-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2021-07-28
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 07/27/2021
UTM: 400KIP
Temperature: 72 f
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 2 | L294Q1 | 1.0000 | 90154 | 401.02 | 10.00 | A325 | fsaylor |
General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Bluehill Data Point FileTest was verified on 7/28/2021 ✔