Summary for Test 2021-07-22-22-4

Test performed: ASTM A416-15

Project Information

Project IdentifiersProject ID: 208973
DEA: 120H1004
EFIS: 1200000180
COOP: 120670
DIST-CO-RTE-PM12-ORA-405,73,405,605-9.3/24.3
Award Date11/07/2016
Closeout DateNot set
Work Description(Alternative Delivery) San Diego Freeway (I-405) Improvement Project SR-73 to I-605, Design Build Project, Administered by Orange County Transportation Authority, Caltrans METS to perform Source Inspection per RFP.
Location DescriptionOrange and Los Angeles Counties: 12-ORA-405 PM 9.3/24.2 / 07-LA-405 PM 0.0/1.2 12-ORA-22 PM R0.7/R3.8 / 12-ORA-22 PM R0.5/R0.7 12-ORA-73 PM R27.2/R27.8 / 12-ORA-605 PM 3.5/R1.6 07-LA-605 PM R0.0/R1.2
QA Service Level1 (Verified on 09/10/2015)

Sample Information

Sample Taken Date07/22/2021 Sample Unique Key22
Date that the sample was received by the laboratory/organization performing the testing07/23/2021 Sample typeQuality Assurance
A brief description of the sample.6in Prestressing Strand The quantity of what the sample constitutes25
From where was the sample collectedManufacturer First name of sampler or witnessed byDon
Last name of sampler or witnessed byHiranaga Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameSumiden Wire
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM4 - Prestressing Strand Comments
Reel/Coil/Pack Number(s) Number of Coils
Group Number10973 Strand Diameter
Grade270 Strand SpecificationASTM A 416
Heat Number(s)S0571421, S0583021, S0572921 Mfg. Lot Number(s)NA
Manufacturer(s)Sumiden Wire

Test Details

DIME Sample ID: 2021-07-22-22
DIME Test ID: 2021-07-22-22-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2021-07-27

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 07/26/2021
UTM: 120kip
Temperature: 72 f
Extensometers: no data
NumHeat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
1S0583021S379759-20.2165994455104.428.31.85bewing

General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 7/27/2021