Summary for Test 2021-07-16-35-8
Test performed: ASTM B499-14Project Information
Project Identifiers | Project ID: 214402 DEA: 010E7704 EFIS: 0115000009 |
---|---|
DIST-CO-RTE-PM | 01-HUM-101-R17.9/87.8 |
Award Date | 01/21/2020 |
Closeout Date | 07/21/2023 |
Work Description | STRENGTHEN 2 BRIDGES. |
Location Description | HUMBOLDT COUNTY AT SOUTH FORK EEL RIVER AND SEPARATION AND AT ARCATA OVERHEAD |
QA Service Level | 1 (Verified on 09/16/2019) |
Sample Information
Sample Taken Date | 07/16/2021 | Sample Unique Key | 35 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/21/2021 |
Sample type | Quality Assurance | A brief description of the sample | 1", 3/4" and 5/8" A325 HDG fastener assemblies |
The quantity of what the sample constitutes | 2138 assemblies total | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Greg | Last name of sampler or witnessed by | Thompson |
Title of sampler | Associate Steel Inspector | Telephone number of sampler | 510-376-7155 |
Laboratory sample identification | Linked DIME Sample ID | 2021-07-16-22 | |
The fabricator/manufacturer/facility name | CK Johnson Industries | Transportation Laboratory (TL) Number | C8356670 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B9-016-21 | Structure unique identifier | |
Structure name | various |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | L171N1R |
---|---|---|---|
Heat Number(s) | Bolt 10629470 Nut 100890602 Washer B57380 | Nut Mfg. Lot Number(s) | 454499A |
Washer Mfg. Lot Number(s) | E0076 | Bolt Specification | A325 Hvy Hex HDG |
Bolt Length(s) | 4" | Nut Specification | F563 DH HDG |
Washer Specification | F436 HDG | Finish | Hot Dip Galvanized |
Diameter/Size | 5/8" dia | Bolt Mfg. Lot Number | L171N1 |
Rocap Test Requirement(s) | yes | Lubricant Requirements(s) | yes |
Test Details
DIME Sample ID: 2021-07-16-35
DIME Test ID: 2021-07-16-35-8
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2021-07-26
Test Results
Input Type: Calculated
Tester's full name: Joshua Gallaway
Date of test: 07/26/2021
Sample No.: 1B
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: L171N1
Finish Coating: Plain and ASTM F2329 - Hot Dip
Product Markings: no data
Size: 0.625 in
Bolt Length: 4 in
Measurement Average: 2.32 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/26/2021 ✔