Summary for Test 2021-07-20-2-2

Test performed: AASHTO T51-13
Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only. Please click this link to view the corrected test.

Project Information

Project IdentifiersProject ID: 44444
DEA: ASCP
EFIS: ASCP
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Asphalt Supplier Certification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date07/20/2021 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/20/2021
Sample typeQuality Control A brief description of the sampleasphalt binder
The quantity of what the sample constitutes2 cans, split sample From where was the sample collectedManufacturer
First name of sampler or witnessed byshawn Last name of sampler or witnessed byShawn
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility name1720 Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
ModifiedNo Lot number
Sublot number Tank number2
Time of sample0700 HMA Supplier
Certified Asphalt SupplierSeventeen Twenty Oil Company - Corona CA MultigradeYes
Multigrade TypePG 64-16 / PG 64-10 Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2021-07-20-2
DIME Test ID: 2021-07-20-2-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T51-13: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Test Release Date: 2021-07-20

Test Results


Is a normal test obtainable?: Yes
Number of replicates tested: Three
Input Type: Measured
Tester's full name: Juan Gomez
Date of test: 07/20/2021
Ductility of test #1 (D1): 120 cm
Ductility of test #2 (D2): 120 cm
Ductility of test #3 (D3): 122 cm
Ductility of sample: 121 cm
General comments (publicly viewable) (Max 1000 characters): 150+

Test was verified on 7/20/2021