Summary for Test 2021-06-30-20-2
Test performed: AASHTO T315-20Project Information
Project Identifiers | Project ID: 215348 DEA: 060U4204 EFIS: 0616000004 |
---|---|
DIST-CO-RTE-PM | 06-FRE-99-R4.9/11.6 |
Award Date | 02/25/2021 |
Closeout Date | Not set |
Work Description | CONSTRUCT CRCP, PLACE HMA, AND ROADWAY EXCAVATION. |
Location Description | FRESNO COUNTY IN AND NEAR SELMA AND FOWLER FROM MCCALL AVENUE UNDERCROSSING TO 0.5 MILE NORTH OF MERCED STREET UNDERCROSSING |
QA Service Level | 1 (Verified on 12/07/2020) |
Sample Information
Sample Taken Date | 06/30/2021 | Sample Unique Key | 20 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/08/2021 |
Sample type | Acceptance | A brief description of the sample | Binder |
The quantity of what the sample constitutes | 1 Can, #2 Test | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Noah | Last name of sampler or witnessed by | Hunt |
Title of sampler | Consultant | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | San Joaquin Refining | Transportation Laboratory (TL) Number | 039805 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 70-10 |
---|---|---|---|
Modified | No | Lot number | 1 |
Sublot number | 2 | Tank number | |
Time of sample | HMA Supplier | ||
Asphalt Binder Supplier | San Joaquin Refinery - Bakersfield CA | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-06-30-20
DIME Test ID: 2021-06-30-20-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-07-14
Test Results
Phase: Original binder
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 07/09/2021
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.00 %
Stress Amplitude: 0.168 kPa
Phase Angle (δ) (for the 10 cycles): 89.5 degree
Complex Modulus (G*) (for the 10 measurements): 1.397 kPa
Test Temperature (Specimen 1): 70.0 C
Dynamic Shear, G*/sin(δ): 1.40 kPa
General comments (publicly viewable) (Max 1000 characters): Per 2018 Standard Specifications ORIG
Test was verified on 7/14/2021 ✔