Summary for Test 2021-05-27-41-5

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 215210
DEA: 030J1804
EFIS: 0319000232
DIST-CO-RTE-PM03-COL-5-6.8
Award Date11/19/2020
Closeout Date03/01/2022
Work DescriptionCONSTRUCT STRUCTURAL CONCRETE BARRIER SLAB AND CONCRETE BARRIER.
Location DescriptionCOLUSA COUNTY AT HILLGATE ROAD UNDERCROSSING (BRIDGE NO. 15-0047)
QA Service Level1 (Verified on 10/05/2020)

Sample Information

Sample Taken Date05/27/2021 Sample Unique Key41
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/28/2021
Sample typeQuality Control A brief description of the samplePortland Cement Concrete
The quantity of what the sample constitutes100 CY From where was the sample collectedJob Site
First name of sampler or witnessed byMichael Last name of sampler or witnessed byThomas
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameHansen Bros Enterprises Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design number8025P-WD3
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected05-195521
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedLOCATION 3 - ABUTMENT 1 CIDH PILES Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2021-05-27-41
DIME Test ID: 2021-05-27-41-5
Testing Lab: RMA Group - Rancho Cordova
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2021-07-04

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Todd Strait
Date of test: 06/24/2021
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 154490 lb
Maximum load on cylinder 2: 146530 lb
Type of fracture pattern of cylinder 1: 5
Type of fracture pattern of cylinder 2: 5
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength (to nearest 10 psi): 5320 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/4/2021