Summary for Test 2021-07-01-7-1

Test performed: AASHTO T315-20

Project Information

Project IdentifiersProject ID: 44444
DEA: ASCP
EFIS: ASCP
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Asphalt Supplier Certification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date07/01/2021 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/01/2021
Sample typeQuality Control A brief description of the sampleAsphalt Binder
The quantity of what the sample constitutes2 quarts cans, split sample From where was the sample collectedSupplier
First name of sampler or witnessed byThomas Last name of sampler or witnessed byLudlum
Title of samplerCOC Program Telephone number of sampler
Laboratory sample identification21-145 Linked DIME Sample ID
The fabricator/manufacturer/facility nameHollyFrontier-Glendale,AZ Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 70-10
ModifiedNo Lot number
Sublot number Tank number533
Time of sample9 am/7-1-2021 HMA Supplier
Certified Asphalt SupplierHolly Frontier Asphalt Company - Glendale AZ MultigradeNo
Multigrade Type Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2021-07-01-7
DIME Test ID: 2021-07-01-7-1
Testing Lab: HollyFrontier Asphalt Company LLC
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-07-02

Test Results


Phase: Original binder
Input Type: Calculated
Tester's full name: Thomas Ludlum
Date of test: 07/01/2021
Test Plate Diameter: 25 mm
Phase Angle (δ) (for the 10 cycles): 88.4 degree
Dynamic Shear, G*/sin(δ): 1.17 kPa
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/2/2021