Summary for Test 2021-06-14-10-12

Test performed: ASTM B499-14

Project Information

Project IdentifiersProject ID: 214922
DEA: 100X3104
EFIS: 1013000265
DIST-CO-RTE-PM10-SJ-99-16.8/17.6
Award Date06/30/2020
Closeout Date04/07/2022
Work DescriptionREPLACE BRIDGE.
Location DescriptionSAN JOAQUIN COUNTY IN STOCKTON FROM 0.4 MILE SOUTH TO 0.4 MILE NORTH OF FARMINGTON ROAD OVERCROSSING
QA Service Level1 (Verified on 04/28/2020)

Sample Information

Sample Taken Date06/14/2021 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/14/2021
Sample typeQuality Assurance A brief description of the sampleA449 Fully threaded Rod, HDG
The quantity of what the sample constitutes465 From where was the sample collectedFabricator
First name of sampler or witnessed byDavid Last name of sampler or witnessed byLund
Title of samplerCT METS QA INSPECTOR Telephone number of sampler1-385-447-0624
Laboratory sample identificationna Linked DIME Sample IDna
The fabricator/manufacturer/facility nameUniversal Industrial Sales Inc Transportation Laboratory (TL) Numberna
Inspector Lot Number from the Transportation Laboratory (TL) FormB390-080-21 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)na
Heat Number(s)10658640 Nut Mfg. Lot Number(s)na
Washer Mfg. Lot Number(s)na Bolt Specificationna
Bolt Length(s)12" Nut Specificationna
Washer Specificationna FinishHDG
Diameter/Size5/8" Bolt Mfg. Lot Number33972
Rocap Test Requirement(s)na Lubricant Requirements(s)na

Test Details

DIME Sample ID: 2021-06-14-10
DIME Test ID: 2021-06-14-10-12
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2021-07-01

Test Results


Input Type: Calculated
Tester's full name: Fred Saylor
Date of test: 07/01/2021
Sample No.: 1E
Rocap Number: no data
Heat Number(s): 10658640
Mfg. Lot Number: 33972
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: A449
Size: .625 in
Bolt Length: 12 in
Measurement Average: 15.3 mils
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/1/2021