Summary for Test 2021-06-07-23-2

Test performed: AASHTO T51-13

Project Information

Project IdentifiersProject ID: 44444
DEA: ASCP
EFIS: ASCP
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Asphalt Supplier Certification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date06/07/2021 Sample Unique Key23
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/17/2021
Sample typeVerification A brief description of the sampleCOC Asphalt Binder
The quantity of what the sample constitutes2 of 2, split sample From where was the sample collectedManufacturer
First name of sampler or witnessed byLuis Last name of sampler or witnessed byTorres
Title of samplerCOC Program Telephone number of sampler
Laboratory sample identification210607-01-7010 Linked DIME Sample ID2021-06-07-22
The fabricator/manufacturer/facility nameWestern Emulsions Inc Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 70-10
ModifiedNo Lot number
Sublot number Tank number50K1
Time of sample8:50 AM HMA Supplier
Certified Asphalt SupplierWestern Emulsions - Coolidge Plant - Coolidge AZ MultigradeNo
Multigrade TypeNot set Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2021-06-07-23
DIME Test ID: 2021-06-07-23-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T51-13: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Test Release Date: 2021-06-30

Test Results


Is a normal test obtainable?: Yes
Number of replicates tested: Two
Input Type: Measured
Tester's full name: Erika Gonzalez
Date of test: 06/29/2021
Ductility of test #1 (D1): 145 cm
Ductility of test #2 (D2): 150 cm
Ductility of sample: 145 cm
General comments (publicly viewable) (Max 1000 characters): per standard specifications

Test was verified on 6/30/2021