Summary for Test 2021-06-08-6-2

Test performed: AASHTO T84-14

Project Information

Project IdentifiersProject ID: 215149
DEA: 081G0104
EFIS: 0815000106
DIST-CO-RTE-PM08-SBD-62-124.8/142.0
Award Date10/21/2020
Closeout Date01/18/2022
Work DescriptionPLACE RHMA-G, HMA, STRUCTURAL CONCRETE & ROCK SLOPE PROTECTION.
Location DescriptionSAN BERNARDINO COUNTY AT VARIOUS LOCATIONS FROM 1.8 MILES WEST OF ROUTE 95 TO 0.3 MILE WEST OF PARKER DAM ROAD.
QA Service Level1 (Verified on 01/28/2021)

Sample Information

Sample Taken Date06/08/2021 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/09/2021
Sample typeVerification A brief description of the samplePSUE 1/2" RHMA-G 0.5% LAS
The quantity of what the sample constitutes3 Bags Combined Agg,3 Bags Rockdust,4 Bags Birds Eye From where was the sample collectedManufacturer
First name of sampler or witnessed byKevin Last name of sampler or witnessed byOluoha
Title of sampler Telephone number of sampler
Laboratory sample identification0344G-21 Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite Construction Company Indio Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0072
The fabricator's/manufacturer's product name for the sample1/2 RHMA-G-SP The fabricator/manufacturer designation for the sample
The plant number1346 A detailed description of where the material sample was collectedBelt Cut at Granite Indio Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number1
Sublot number1 Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2021-06-08-6
DIME Test ID: 2021-06-08-6-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2021-06-24

Test Results


Input Type: Measured
Tester's full name: Michael Magana
Date of test: 06/11/2021
Mass of saturated surface dry sample (before pycnometer) (S): 500 grams
Mass of the pycnometer with water and aggregate (C): 965.3 grams
Mass of the pycnometer with water (B): 653.3 grams
Mass of the oven dried sample (before pycnometer) (A): 497 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500 grams
Mass of the oven dry aggregate (for absorption) (A): 497 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity: 2.644
Bulk specific gravity (SSD Basis): 2.660
Apparent specific gravity: 2.686
Absorption: 0.6 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/24/2021