Summary for Test 2021-06-10-4-1
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 215063 DEA: 032F5704 EFIS: 0300020615 |
---|---|
DIST-CO-RTE-PM | 03-PLA-80-46.3/63.5 |
Award Date | 09/23/2020 |
Closeout Date | 08/11/2023 |
Work Description | Replace 4 Bridges (OC) on Highway 80 from Crystal Springs to Cisco Grove (Baxter, Drum Forebay) |
Location Description | Not set |
QA Service Level | 1 (Verified on 11/16/2020) |
Sample Information
Sample Taken Date | 06/10/2021 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/14/2021 |
Sample type | Quality Assurance | A brief description of the sample | High Strength Fastener Assemblies |
The quantity of what the sample constitutes | 7 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Paul | Last name of sampler or witnessed by | Farinha |
Title of sampler | ASSOC STEEL INSP | Telephone number of sampler | 9167987102 |
Laboratory sample identification | Linked DIME Sample ID | 2021-06-10-5, 2021-06-10-6 | |
The fabricator/manufacturer/facility name | SSP Fort Worth | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S51-33-21 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 5/27/21A |
---|---|---|---|
Heat Number(s) | 100206586 | Nut Mfg. Lot Number(s) | |
Washer Mfg. Lot Number(s) | Bolt Specification | A325 | |
Bolt Length(s) | 2-1/2 | Nut Specification | N/A |
Washer Specification | N/A | Finish | Galvanized |
Diameter/Size | 3/4"-10 | Bolt Mfg. Lot Number | 449993A |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2021-06-10-4
DIME Test ID: 2021-06-10-4-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2021-06-16
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 06/15/2021
UTM: 450kip
Temperature: no data
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 1A | 449993A | 0.7500 | 46591 | 207.25 | 10.00 | A325 Wedge Tensile | spaine |
General comments (publicly viewable) (Max 1000 characters): A325 Wedge Tensile
Test Graph
Source: Bluehill Data Point FileTest was verified on 6/16/2021 ✔