Summary for Test 2021-05-27-25-8

Test performed: AASHTO T335-09r13

Project Information

Project IdentifiersProject ID: 215236
DEA: 081C6804
EFIS: 0812000343
DIST-CO-RTE-PM08-RIV-74,79and371-Varies
Award Date12/29/2020
Closeout DateNot set
Work DescriptionREPLACE STRUCTURAL CONCRETE BRIDGE, RETAINING WALL AND BOX CULVERT.
Location DescriptionRIVERSIDE COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 03/02/2021)

Sample Information

Sample Taken Date05/27/2021 Sample Unique Key25
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/02/2021
Sample typeVerification A brief description of the sampleJMF 1/2" HMA-A-SP R25 0.5% LAS
The quantity of what the sample constitutes6 Bags Coldfeed Aggregate 3 Bags RAP From where was the sample collectedManufacturer
First name of sampler or witnessed byCalifornia Commercial Asphalt Lake Elsinore Last name of sampler or witnessed byQC
Title of sampler Telephone number of sampler
Laboratory sample identification0321A-21 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCalifornia Commercial Asphalt - Lake Elsinore Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0098, 91-33-0011
The fabricator's/manufacturer's product name for the sample1/2 HMA-A-SP R25 The fabricator/manufacturer designation for the sample
The plant number51217615 A detailed description of where the material sample was collectedBelt Cut at California Commercial Asphalt Lake Elsinore Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2021-05-27-25
DIME Test ID: 2021-05-27-25-8
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Test Release Date: 2021-06-09

Test Results


Method: 1 - Combined Fracture Determination
Aggregate Size and Fracture Type: Coarse 1 and 2 Faced and Fine 1 Faced
Input Type: Calculated
Tester's full name: Satish Jain
Date of test: 06/08/2021
Percentage of fractured, coarse, 2 faced particles tested: 100 %
Percentage of fractured, coarse, 1 faced particles tested: 100 %
Percentage of fractured, fine, 1 faced particles tested: 100 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/9/2021