Summary for Test 2021-04-04-4-2

Test performed: CTM 301-March 2000

Project Information

Project IdentifiersProject ID: 212501
DEA: 022E4804
EFIS: 0200000586
DIST-CO-RTE-PM02-SIS-96,263-103.1/103.6,56.8/57.2
Award Date12/14/2018
Closeout Date12/01/2021
Work DescriptionBRIDGE REPLACEMENT
Location DescriptionSISKIYOU COUNTY ABOUT 8 MILES NORTH OF YREKA ON ROUTE 96 FROM 0.5 MILE WEST TO 0.2 MILE EAST OF ROUTE 263 AND ON ROUTE 263 FROM 0.3 MILE NORTH OF SHASTA RIVER BRIDGE #02-0014 TO ROUTE 96
QA Service Level1 (Verified on 06/06/2017)

Sample Information

Sample Taken Date04/04/2021 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/12/2021
Sample typeAcceptance A brief description of the sample3/4-inch Maximum Class 2 Aggregate Base
The quantity of what the sample constitutesUndefined From where was the sample collectedJob Site
First name of sampler or witnessed byDanny Last name of sampler or witnessed byHanson
Title of sampler Telephone number of sampler
Laboratory sample identificationD78773 Linked DIME Sample ID
The fabricator/manufacturer/facility nameMeyers - Anderson Grade Transportation Laboratory (TL) Number897283
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Undefined
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedRoadway
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2021-04-04-4
DIME Test ID: 2021-04-04-4-2
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 301-March 2000: Method for Determining the Resistance "R" Value of Treated and Untreated Bases, Subbases, and Basement Soils by the Stabilometer
Test Release Date: 2021-06-07

Test Results


How will the R value be determined?: By stabilometer
Input Type: Measured
Tester's full name: Dennis Hickey
Date of test: 04/19/2021
As Received Gradation, Percent Passing 3 in. sieve: 100 %
As Received Gradation, Percent Passing 2 1/2 in. sieve: 100 %
As Received Gradation, Percent Passing 2 in. sieve: 100 %
As Received Gradation, Percent Passing 1 1/2 in. sieve: 100 %
As Received Gradation, Percent Passing 1 in. sieve: 100 %
As Received Gradation, Percent Passing 3/4 in. sieve: 95 %
As Received Gradation, Percent Passing 1/2 in. sieve: 73 %
As Received Gradation, Percent Passing 3/8 in. sieve: 61 %
As Received Gradation, Percent Passing #4 sieve: 41 %
As Received Gradation, Percent Passing #8 sieve: 28 %
As Received Gradation, Percent Passing #16 sieve: 20 %
As Received Gradation, Percent Passing #30 sieve: 15 %
As Received Gradation, Percent Passing #50 sieve: 11 %
As Received Gradation, Percent Passing #100 sieve: 9 %
As Received Gradation, Percent Passing #200 sieve: 7 %
As Used Gradation, Percent Passing 3 in. sieve: 100 %
As Used Gradation, Percent Passing 2 1/2 in. sieve: 100 %
As Used Gradation, Percent Passing 2 in. sieve: 100 %
As Used Gradation, Percent Passing 1 1/2 in. sieve: 100 %
As Used Gradation, Percent Passing 1 in. sieve: 100 %
As Used Gradation, Percent Passing 3/4 in. sieve: 100 %
As Used Gradation, Percent Passing 1/2 in. sieve: 77 %
As Used Gradation, Percent Passing 3/8 in. sieve: 64 %
As Used Gradation, Percent Passing #4 sieve: 43 %
As Used Gradation, Percent Passing #8 sieve: 29 %
As Used Gradation, Percent Passing #16 sieve: 21 %
As Used Gradation, Percent Passing #30 sieve: 16 %
As Used Gradation, Percent Passing #50 sieve: 12 %
As Used Gradation, Percent Passing #100 sieve: 9 %
As Used Gradation, Percent Passing #200 sieve: 7 %
Horizontal pressure (specimen 1): 0.11 MPa
Displacement (specimen 1): 4.71
Horizontal pressure (specimen 2): 0.12 MPa
Displacement (specimen 2): 5.35
Horizontal pressure (specimen 3): 0.18 MPa
Displacement (specimen 3): 5.75
R value (specimen 1): 82.7
R value (specimen 2): 79.2
R value (specimen 3): 69
R value: 72
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/7/2021