Summary for Test 2015-07-21-2-1

Test performed: CTM 521-November 2014

Project Information

Project IdentifiersProject ID: 209503
DEA: 11257154
EFIS: 1100020489
DIST-CO-RTE-PM11-SD-76,15-R46.2/R46.8, R12.1/R17.7
Award Date08/04/2014
Closeout Date08/16/2021
Work DescriptionCONSTRUCT 4 LANE HIGHWAY.
Location DescriptionSAN DIEGO COUNTY NEAR BONSALL AND FALLBROOK ON ROUTE 15 FROM 0.3 MILE SOUTH TO 0.3 MILE NORTH OF ROUTE 76/15 SEPARATION AND ON ROUTE 76 FROM 0.4 MILE WEST OF SOUTH MISSION ROAD TO 0.5 MILE EAST OF ROUTE 76/15 SEPARATION
QA Service Level1 (Verified on 08/25/2014)

Sample Information

Sample Taken Date07/21/2015 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/23/2015
Sample typeQuality Control A brief description of the sample6X12
The quantity of what the sample constitutes2 From where was the sample collectedJob Site
First name of sampler or witnessed byDAVID Last name of sampler or witnessed byWEEKS
Title of samplerCALTRANS METS QA INSPECTOR Telephone number of sampler951-258-8382
Laboratory sample identification913-01 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameJOB Transportation Laboratory (TL) NumberL79 CSIP 001
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierCONSTRUCT 4 LANE HWY
Structure nameCASTING BED 9 GIRDER G1 8

Material Information

Material TypeConcrete The concrete mix design number1457-1
The truck number from where the sample was collectedLOAD 7 The batch plant ticket number from where the sample was collected56933
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedTUCKER DISCHARGE Where the material sample would have been placed if not sampledUnknown
From Lot No.Not set Bag Lot No.Not set

Test Details

DIME Sample ID: 2015-07-21-2
DIME Test ID: 2015-07-21-2-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 521-November 2014: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2015-07-28

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 07/28/2015
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 6.01 in
Maximum load on cylinder 1: 267190 lb
Maximum load on cylinder 2: 270990 lb
Type of fracture pattern of cylinder 1: 4
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Age of specimen: 7 days
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 28.37 in^2
Compressive strength of cylinder 1: 9418 psi
Compressive strength of cylinder 2: 9552 psi
Compressive strength (to nearest 10 psi): 9490 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/28/2015