Summary for Test 2021-05-25-6-3

Test performed: AASHTO T84-14

Project Information

Project IdentifiersProject ID: 214216
DEA: 071XM404
EFIS: 0719000232
DIST-CO-RTE-PM07-VEN-33-22.16, 22.16
Award Date06/21/2019
Closeout Date10/06/2022
Work DescriptionThis is the emergency project to repair pavement cracking, stabilize the eroded slope, construct a soldier pile tieback wall and reconstruct the steel post MGS
Location DescriptionVentura County on Route 33 at PM.22.16.
QA Service Level1 (Verified on 08/27/2019)

Sample Information

Sample Taken Date05/25/2021 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/27/2021
Sample typeVerification A brief description of the samplePSUE 3/4" HMA-A-SP R25 No LAS
The quantity of what the sample constitutes4 Bags Coldfeed Agg., 1 Bag Rap From where was the sample collectedManufacturer
First name of sampler or witnessed byHonesto Last name of sampler or witnessed byCastillo
Title of sampler Telephone number of sampler
Laboratory sample identification0309A-21 Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite Construction Company Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0046::BIG ROCK CREEK- GRANITE
The fabricator's/manufacturer's product name for the sample3/4 HMA-A-SP R25 The fabricator/manufacturer designation for the sample
The plant number13762 A detailed description of where the material sample was collectedBelt Cutat Granite Construction Company
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number1
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2021-05-25-6
DIME Test ID: 2021-05-25-6-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2021-06-08

Test Results


Input Type: Measured
Tester's full name: Danilo Ferrer
Date of test: 06/02/2021
Mass of saturated surface dry sample (before pycnometer) (S): 500 grams
Mass of the pycnometer with water and aggregate (C): 968.8 grams
Mass of the pycnometer with water (B): 653.2 grams
Mass of the oven dried sample (before pycnometer) (A): 495.4 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500 grams
Mass of the oven dry aggregate (for absorption) (A): 495.4 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity: 2.687
Bulk specific gravity (SSD Basis): 2.711
Apparent specific gravity: 2.755
Absorption: 0.9 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/8/2021