Summary for Test 2021-04-01-34-2

Test performed: AASHTO T209-12

Project Information

Project IdentifiersProject ID: 215062
DEA: 030F2904
EFIS: 0314000101
DIST-CO-RTE-PM03-BUT-99-14.9/15.7
Award Date09/24/2020
Closeout Date03/02/2022
Work DescriptionCONSTRUCT BRIDGE AND ROADWAY; & REMOVE BRIDGE.
Location DescriptionBUTTE COUNTY ABOUT 10 MILES NORTH OF GRIDLEY FROM 0.3 MILE SOUTH TO 0.5 MILE NORTH OF NELSON AVENUE
QA Service Level1 (Verified on 07/20/2020)

Sample Information

Sample Taken Date04/01/2021 Sample Unique Key34
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/01/2021
Sample typeVerification A brief description of the sampleRAP
The quantity of what the sample constitutesJMF Verification From where was the sample collectedManufacturer
First name of sampler or witnessed byTeichert Personnel (SAMPLER) Last name of sampler or witnessed by Brad McKeehan (WITNESS)
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample IDJMF21-020B
The fabricator/manufacturer/facility nameTeichert - Hallwood Plant Transportation Laboratory (TL) NumberC706327
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeReclaimed Asphalt Pavement RAP SourceTeichert Hallwood RAP Bin 1
Aggregate Size Aggregate Source
RAP StockpileStatic Stockpile Size (tons)Unknown
Reclaimed Asphalt Pavement Mix NumberNot set

Test Details

DIME Sample ID: 2021-04-01-34
DIME Test ID: 2021-04-01-34-2
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2021-06-03

Test Results


Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Mario Munoz
Date of test: 04/28/2021
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7346.6 grams
Mass of oven-dry sample in air for Sample 1: 1275.0 grams
Mass of container filled with the sample and water for Sample 1: 8138.9 grams
Temperature of Water: 76 °F
Specific Gravity for Sample 1: 2.641
Theoretical maximum density at 25°C (77°F): no data
General comments (publicly viewable) (Max 1000 characters): JMF21-020B.

Test was verified on 6/3/2021