Summary for Test 2021-05-17-7-4

Test performed: AASHTO T84-14

Project Information

Project IdentifiersProject ID: 215309
DEA: 09385904
DIST-CO-RTE-PM09-KER-14-R12.6/L16.2
Award Date01/29/2021
Closeout Date06/30/2021
Work DescriptionCOLD PLANE AND PLACE HMA (TYPE A).
Location DescriptionKERN COUNTY AT AND NEAR MOJAVE FROM 0.5 MILE NORTH OF SILVER QUEEN ROAD OVERCROSSING TO 0.1 MILE NORTH OF BUSINESS 58 EAST
QA Service Level1 (Verified on 06/23/2021)

Sample Information

Sample Taken Date05/17/2021 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/19/2021
Sample typeVerification A brief description of the samplePSUE 3/4" HMA-A-SP R15 1.0% LAS
The quantity of what the sample constitutes4 Bags Coldfeed Agg., 1 Bag Rap From where was the sample collectedManufacturer
First name of sampler or witnessed byS Last name of sampler or witnessed byAhumada
Title of sampler Telephone number of sampler
Laboratory sample identification0289A-21 Linked DIME Sample ID
The fabricator/manufacturer/facility nameGriffith Edmonston-Lebec Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-15-0068
The fabricator's/manufacturer's product name for the sample3/4 HMA-A-SP R15 The fabricator/manufacturer designation for the sample
The plant numberGRF 15 G3 2 A detailed description of where the material sample was collectedBelt Cut at Griffith Edmonston
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2021-05-17-7
DIME Test ID: 2021-05-17-7-4
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2021-06-02

Test Results


Input Type: Measured
Tester's full name: Friday Ofoegbu
Date of test: 05/27/2021
Mass of saturated surface dry sample (before pycnometer) (S): 500 grams
Mass of the pycnometer with water and aggregate (C): 972.2 grams
Mass of the pycnometer with water (B): 653.2 grams
Mass of the oven dried sample (before pycnometer) (A): 493.9 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500 grams
Mass of the oven dry aggregate (for absorption) (A): 493.9 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity: 2.729
Bulk specific gravity (SSD Basis): 2.762
Apparent specific gravity: 2.824
Absorption: 1.2 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/2/2021