Summary for Test 2021-05-12-43-6

Test performed: AASHTO T176-08

Project Information

Project IdentifiersProject ID: 214665
DEA: 081G5504
EFIS: 0816000035
DIST-CO-RTE-PM08-SBD-40-R28.9
Award Date03/09/2021
Closeout Date01/18/2022
Work DescriptionREPLACE WEIGH-IN-MOTION SYSTEM WITH HIGH SPEED WEIGH-IN-MOTION SYSTEM.
Location DescriptionSAN BERNARDINO COUNTY NEAR NEWBERRY SPRINGS AT 3.6 MILES WEST OF HECTOR ROAD UNDERCROSSING
QA Service Level1 (Verified on 06/23/2021)

Sample Information

Sample Taken Date05/12/2021 Sample Unique Key43
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/24/2021
Sample typeVerification A brief description of the sampleJMF 3/4" HMA-A-SP R15 0.75% LAS
The quantity of what the sample constitutes12 Bags Agg., 2 Bags Rap From where was the sample collectedManufacturer
First name of sampler or witnessed byVulcan Oro Grande Last name of sampler or witnessed byQC
Title of sampler Telephone number of sampler
Laboratory sample identification0299A-21 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Materials-Oro Grande Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-36-0022/91-36-0046/91-36-00137
The fabricator's/manufacturer's product name for the sample3/4 HMA-A-SP R15 The fabricator/manufacturer designation for the sample
The plant number224112 ORO MPC A detailed description of where the material sample was collectedBelt Cut at Vulcan Oro Grande Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2021-05-12-43
DIME Test ID: 2021-05-12-43-6
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2021-06-02

Test Results


How many times will the test be run?: 3 Times
Input Type: Measured
Tester's full name: F.Ofoegbu
Date of test: 06/02/2021
Clay Level (Test 1): 5.5
Sand Level (Test 1): 3.6
Clay Level (Test 2): 5.4
Sand Level (Test 2): 3.6
Clay Level (Test 3): 5.5
Sand Level (Test 3): 3.6
Sand Equivalent (Test 1): 66
Sand Equivalent (Test 2): 67
Sand Equivalent (Test 3): 66
Sand Equivalent: 67