Summary for Test 2021-05-10-27-4

Test performed: AASHTO T315-16

Project Information

Project IdentifiersProject ID: 215092
DEA: 101C0404
EFIS: 1017000034
DIST-CO-RTE-PM10-MPA-49-0.3/18.5
Award Date10/01/2020
Closeout Date06/27/2022
Work DescriptionCOLD PLANE, PLACE HMA AND REPLACE RAILING AND OVERSIDE DRAINS.
Location DescriptionMARIPOSA COUNTY IN AND NEAR MARIPOSA FROM MADERA COUNTY LINE TO SOUTH JUNCTION ROUTE 140
QA Service Level1 (Verified on 08/20/2020)

Sample Information

Sample Taken Date05/10/2021 Sample Unique Key27
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/21/2021
Sample typeAcceptance A brief description of the samplePG64-10
The quantity of what the sample constitutes1 of 2 cans From where was the sample collectedManufacturer
First name of sampler or witnessed byAdam Last name of sampler or witnessed byZ
Title of samplerARE Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameTeichert - Santa Fe Winton Transportation Laboratory (TL) Numberc994286
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 64-10
ModifiedNo Lot number1
Sublot number1 Tank number
Time of sample HMA SupplierTeichert - Santa Fe Winton
Certified Asphalt SupplierMarathon Petroleum Co. LP - Elk Grove CA MultigradeNo
Multigrade TypeNot set Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2021-05-10-27
DIME Test ID: 2021-05-10-27-4
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-06-01

Test Results


Phase: PAV residue
Input Type: Measured
Tester's full name: Harish Thakur
Date of test: 05/27/2021
Test Plate Diameter: 8 mm
Test Gap: 2 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 1.00 %
Stress Amplitude: 34.535 kPa
Phase Angle (δ) (for the 10 cycles): 50.3 degree
Complex Modulus (G*) (for the 10 measurements): 3453.103 kPa
Test Temperature (Specimen 1): 31.0 C
(G*) x sin(δ)=: 2657 kPa
General comments (publicly viewable) (Max 1000 characters): PAV

Test was verified on 6/1/2021