Summary for Test 2021-05-06-17-4

Test performed: AASHTO T315-16
Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only.

Project Information

Project IdentifiersProject ID: 214874
DEA: 022H0504
EFIS: 0216000093
DIST-CO-RTE-PM02-TRI-36-R34.8/R35.4
Award Date05/27/2020
Closeout Date09/27/2021
Work DescriptionREALIGN ROADWAY, DRAINAGE, GUARDRAIL, AND EROSION CONTROL.
Location DescriptionTRINITY COUNTY ABOUT 15 MILES WEST OF PLATINA FROM 3.6 MILES TO 2.9 MILES WEST OF HAYFORK CREEK BRIDGE.
QA Service Level1 (Verified on 05/26/2020)

Sample Information

Sample Taken Date05/06/2021 Sample Unique Key17
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/20/2021
Sample typeAcceptance A brief description of the samplePG64-28M
The quantity of what the sample constitutes1 of 1 can From where was the sample collectedManufacturer
First name of sampler or witnessed byno TL101 tag Last name of sampler or witnessed byno TL 101 tag
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameKnife River - Orland Transportation Laboratory (TL) Numberc768290 marked on can
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 64-28 M
ModifiedYes Lot number1
Sublot number1 Tank number
Time of sample HMA SupplierKnife River - Orland
Certified Asphalt SupplierMarathon Petroleum Co. LP - Elk Grove CA MultigradeNo
Multigrade TypeNot set Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2021-05-06-17
DIME Test ID: 2021-05-06-17-4
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-05-28

Test Results


Phase: RTFO residue
Input Type: Measured
Tester's full name: Harish Thakur
Date of test: 05/25/2021
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 10.00 %
Stress Amplitude: 0.365 kPa
Phase Angle (δ) (for the 10 cycles): 68.0 degree
Complex Modulus (G*) (for the 10 measurements): 3.648 kPa
Test Temperature (Specimen 1): 64.0 C
Dynamic Shear, G*/sin(δ): 3.93 kPa
General comments (publicly viewable) (Max 1000 characters): RTFOPer 2018 Standard Specifications

Test was verified on 5/28/2021