Summary for Test 2021-05-20-3-1

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 215032
DEA: 030H5204
EFIS: 0315000202
DIST-CO-RTE-PM03-ED-50-0.0/80.4
Award Date08/13/2020
Closeout Date07/26/2023
Work DescriptionINSTALL CMS, CAMERA SYSTEMS AND TMS ELEMENTS.
Location DescriptionEL DORADO COUNTY AT VARIOUS LOCATIONS FROM THE SACRAMENTO COUNTY LINE TO CALIFORNIA/NEVADA STATE LINE
QA Service Level1 (Verified on 07/20/2020)

Sample Information

Sample Taken Date05/20/2021 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/24/2021
Sample typeQuality Assurance A brief description of the sample3/4-10 /UNC X 2.5" Bolt
The quantity of what the sample constitutes7 Bolts From where was the sample collectedFabricator
First name of sampler or witnessed byPaul Last name of sampler or witnessed byFarinha
Title of samplerASSOC STEEL INSP Telephone number of sampler9167987102
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameStructural and Steel Products Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormS51-31-20 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)3/31/21E
Heat Number(s)1000205944 Nut Mfg. Lot Number(s)N/A
Washer Mfg. Lot Number(s)N/A Bolt SpecificationN/A
Bolt Length(s)N/A Nut SpecificationN/A
Washer SpecificationN/A FinishHot Dip Galve
Diameter/Size3/4" X 2 1/2" Bolt Mfg. Lot Number446296A
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2021-05-20-3
DIME Test ID: 2021-05-20-3-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2021-05-26

Test Results


Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 05/24/2021
UTM: 450kip
Temperature: no data
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
11446296A0.750047546211.4910.00A325fsaylor

General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Bluehill Data Point File

Test was verified on 5/26/2021