Summary for Test 2021-04-16-32-6
Test performed: CTM 229-June 2011Project Information
Project Identifiers | Project ID: 66666 DEA: APP EFIS: 0019000052 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 04/16/2021 | Sample Unique Key | 32 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/16/2021 |
Sample type | Aggregate Prequalification Program | A brief description of the sample | Fine PCC Aggregate |
The quantity of what the sample constitutes | 4 Bags | From where was the sample collected | Source |
First name of sampler or witnessed by | Marc | Last name of sampler or witnessed by | Segura |
Title of sampler | QC Supervisor | Telephone number of sampler | 9094368680 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Cemex Moorpark | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-56-0014::MOORPARK |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | 4425 | A detailed description of where the material sample was collected | Production stockpile |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | fine | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2021-04-16-32
DIME Test ID: 2021-04-16-32-6
Testing Lab: CEMEX - Central & Southern California
Test Method: CTM 229-June 2011: Method of Test for Durability Index
Test Release Date: 2021-05-18
Test Results
What test(s) are being run?: Fine durability only
Input Type: Calculated
Tester's full name: Marc Segura
Date of test: 04/16/2021
Fine durability index: 72
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/18/2021 ✔