Summary for Test 2021-05-13-7-2

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 214355
DEA: 120K0214
EFIS: 1214000096
DIST-CO-RTE-PM12-ORA-5-12.4/14.5
Award Date12/20/2019
Closeout DateNot set
Work DescriptionSouth County Improvement Project (Phase 1 - Avery/Crown Valley) PLACE HMA, INSTALL CONC PAVEMENT, RETAIN WALL, MODIFY ELECT SYS. | Add one lane btwn 73 & Oso PKWY
Location DescriptionORANGE COUNTY IN SAN JUAN CAPISTRANO, LAGUNA HILLS, LAGUNA NIGUEL AND MISSION VIEJO FROM 0.5 MILE SOUTH OF AVERY PARKWAY UNDERCROSSING TO 0.8 MILE NORTH OF CROWN VALLEY PARKWAY OVERCROSSING
QA Service Level1 (Verified on 10/31/2019)

Sample Information

Sample Taken Date05/13/2021 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/14/2021
Sample typeQuality Assurance A brief description of the sampleLENTON FORM SAVER (Sleeve-Tapered Thread)
The quantity of what the sample constitutes(4) LENTON FORM SAVER (Sleeve-Tapered Thread) From where was the sample collectedManufacturer
First name of sampler or witnessed byRigoberto Last name of sampler or witnessed byMarin
Title of samplerAMR Telephone number of sampler9515000685
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCoreslab Structures L A Inc Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL133-058-21 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC Steel Arizona
Coupler ManufacturerErico nVent Intermediate Assembler or FabricatorCoreslab Structures L A Inc
Rebar Size#8 Coupler ModelST-17-05
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop FabricatorNA
Coupler Component Heat/Lot Number(s)L9814 Rebar Heat Number(s)4102817
Rebar Size 2 8 Coupler Unique IDNot set

Test Details

DIME Sample ID: 2021-05-13-7
DIME Test ID: 2021-05-13-7-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2021-05-18

Test Results


Number of Samples Tested: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 05/14/2021
UTM: 400kip
Temperature: 72.00 f
Halo ID:
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
12No. 8/25mm100.797765998302Service Splicefsaylor

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 5/18/2021