Summary for Test 2021-04-29-1-1

Test performed: ASTM A970-15e1

Project Information

Project IdentifiersProject ID: 215063
DEA: 032F5704
EFIS: 0300020615
DIST-CO-RTE-PM03-PLA-80-46.3/63.5
Award Date09/23/2020
Closeout Date08/11/2023
Work DescriptionReplace 4 Bridges (OC) on Highway 80 from Crystal Springs to Cisco Grove (Baxter, Drum Forebay)
Location DescriptionNot set
QA Service Level1 (Verified on 11/16/2020)

Sample Information

Sample Taken Date04/29/2021 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/30/2021
Sample typeQuality Assurance A brief description of the sampleHRC 120 #5 headed rebar with hook
The quantity of what the sample constitutes2322 From where was the sample collectedFabricator
First name of sampler or witnessed bySteven Last name of sampler or witnessed byHall
Title of samplerCT METS QA INSPECTOR Telephone number of sampler6466327821
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameHeaded Reinforcement Corp, Fountain Valley, CA Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL134-062-21 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)2120765 Head Manufacturer Lot Number(s)1, 4, 9 and 14
Rebar Size#5 Headed Bar Model NameHRC 120
Size of HeadFull Size - 9x Head Connection TypeFriction Weld
Head ShapeSquare Rebar ManufacturerVinton Steel
Head ManufacturerHeaded Reinforcement Corp Head FabricatorHeaded Reinforcement Corp
Material Standard CodeASTM A706 Headed Bar Unique IDNot set

Test Details

DIME Sample ID: 2021-04-29-1
DIME Test ID: 2021-04-29-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2021-05-05

Test Results


Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 05/04/2021
UTM: 400kip
Temperature: 72 f
NumLot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
110.312867292492Ok neckingbewing

General comments (publicly viewable) (Max 1000 characters): Ok necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 5/5/2021