Summary for Test 2021-04-21-18-6

Test performed: AASHTO T315-16

Project Information

Project IdentifiersProject ID: 209520
DEA: 06470904
EFIS: 0600000973
COOP: 061529
DIST-CO-RTE-PM06-MAD-99-R7.5/15.1
Award Date03/14/2019
Closeout Date05/11/2023
Work DescriptionWIDEN FREEWAY FROM 4 LANES TO 6 LANES.
Location DescriptionMADERA COUNTY IN AND NEAR MADERA FROM AVENUE 12 OVERCROSSING TO 0.9 MILE NORTH OF AVENUE 17 OVERCROSSING
QA Service Level1 (Verified on 03/16/2016)

Sample Information

Sample Taken Date04/21/2021 Sample Unique Key18
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/28/2021
Sample typeAcceptance A brief description of the sampleAsphalt Binder
The quantity of what the sample constitutes1 of 1 can From where was the sample collectedManufacturer
First name of sampler or witnessed byG Last name of sampler or witnessed bydih
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Madera Transportation Laboratory (TL) Numberc816159
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 70-10
ModifiedNo Lot number10
Sublot number3 Tank number
Time of sample HMA SupplierVulcan Madera
Certified Asphalt SupplierSan Joaquin Refinery - Bakersfield CA MultigradeNo
Multigrade TypeNot set Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2021-04-21-18
DIME Test ID: 2021-04-21-18-6
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-05-05

Test Results


Phase: RTFO residue
Input Type: Measured
Tester's full name: Erika Gonzalez
Date of test: 05/03/2021
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 10.00 %
Stress Amplitude: 0.209 kPa
Phase Angle (δ) (for the 10 cycles): 88.9 degree
Complex Modulus (G*) (for the 10 measurements): 2.094 kPa
Test Temperature (Specimen 1): 70.0 C
Dynamic Shear, G*/sin(δ): 2.09 kPa
General comments (publicly viewable) (Max 1000 characters): per standard specifications RTFO2

Test was verified on 5/5/2021